Isolated analog output: 4-channel universal-range version, or single-channel high-voltage version with output up to 1 kV on an MHV connector. The board can hold a constant level, be driven manually or generate arbitrary user-defined waveforms up to 500 kS/s, configured in corus Studio and synchronised with the acquisition.
Analog output
Description
Specifications
Values declared by the manufacturer. For test measurements or customisations, request the technical documentation.
Output modes
| Mode | Duration | Description |
|---|---|---|
| Manual | Any time | Output level set live by the operator from corus Studio, independent of the recording. |
| Constant | Whole recording | Fixed output level held for the entire acquisition. |
| Constant | Programmed time | Fixed output level held for a programmed time from the start of the acquisition. |
| Function generator | Whole recording, loop | User-defined waveform repeated continuously for the entire acquisition. |
| Function generator | Single cycle | User-defined waveform played once per recording, from the start of the acquisition. |
Order codes
Every code is a product: open it for details or save it to the wishlist with the heart.
Order codeChannelsOutput rangePanel mmWishlist